CSI 05 12 00 — Structural Steel Framing
ASTM A500 Grade C mill test report checklist
Standard Specification for Cold-Formed Welded and Seamless Carbon Steel Structural Tubing
Chemistry (% by weight)
- Carbon (C)
- ≤ 0.23%
- Manganese (Mn)
- ≤ 1.35%
- Phosphorus (P)
- ≤ 0.035%
- Sulfur (S)
- ≤ 0.035%
Tensile requirements
- Yield strength
- ≥ 50 ksi
- Tensile strength
- ≥ 62 ksi
- Elongation in 2 in.
- ≥ 21%
Build America, Buy America
2 CFR 184.3On federally funded infrastructure, ASTM A500 Grade C material is an iron or steel product: every process from initial melting through coating must happen in the United States. The mill test report should show a U.S. melt and pour location for each heat.
Edition, notes and sources
Checked against A500/A500M-23- Minimum yield is 50 ksi for shaped (square and rectangular) tubing and 46 ksi for round tubing.
- Limits shown are heat analysis. Copper ≥ 0.20% applies only when copper-bearing steel is specified.
Sources
ASTM standards are copyrighted. These limits were cross-checked against published summaries; confirm them against a licensed copy of the edition your specification cites.
Reviewing an ASTM A500 Grade C mill test report
- Confirm the MTR names ASTM A500 Grade C (or a dual certification that includes it).
- Match the heat number on the MTR to the heat stamped on each delivered piece.
- Compare the heat analysis with the chemistry limits above.
- Compare the tensile results with the yield, tensile and elongation minimums.
- On BABA work, confirm the country of melt and pour is the United States.